Abstrato

Electrochemical Characterization of Xipamide Using Cyclic and Square Wave Voltammetry

Attia AK, and Hendawy HM


The electrochemical behaviour of xipamide was studied at glassy carbon electrode in Britton-Robinson buffer solution of different pH values ranging from 2.0 to 7.0 using cyclic voltammetry and square wave voltammetry. Voltammetric results showed a reversible redox and diffusion-controlled process. The oxidation and reduction peaks were found at potentials of 0.375 V and 0.321 V at pH 5.0, respectively. While the reported voltammetric method 2 shows irreversible oxidation process for xipamide and having higher detection limit than the proposed method. Linear responses were obtained over concentration ranges of 5.0 × 10-8 to 6.46 × 10-7 mol L-1 and 5.0 × 10-8 to 9.90 × 10-7 mol L-1 with detection limits of 3.97 × 10-9 mol L-1 and 3.30 × 10-9 mol L-1 for oxidation and reduction processes, respectively. Sensitivity, precision and accuracy were evaluated. The proposed method is suitable for the quality control of xipamide in bulk, commercial formulations and urine.


Isenção de responsabilidade: Este resumo foi traduzido usando ferramentas de inteligência artificial e ainda não foi revisado ou verificado

Indexado em

  • CASS
  • Google Scholar
  • Abra o portão J
  • Infraestrutura Nacional de Conhecimento da China (CNKI)
  • CiteFactor
  • Cosmos SE
  • Biblioteca de Periódicos Eletrônicos
  • Diretório de indexação de periódicos de pesquisa (DRJI)
  • Laboratórios secretos de mecanismos de pesquisa
  • ICMJE

Veja mais

Flyer